Gliderol and Glidermatic Troubleshooting Guide

Trouble with your Gliderol garage door? When it comes to garage door repair and safety, it is always best to have a professional technician assess the issue. We assess it for free, in most cases the same day, anywhere across Perth. If you would rather take a look yourself first, work through the safe troubleshooting checks below.

  • All Perth covered
  • No call-out fee
  • Same-day service
  • Fixed price before we start

Gliderol troubleshooting depends on the opener. A Glidermatic GRD sits inside the roll with a red lever at the end of the curtain. A Rollamatic GEN II sits beside the roll with a round panel and a red ball on a cord. A Genesis hangs from the ceiling with a two-digit display. Find yours, then use the codes and checks below.

What the lights and beeps mean

Gliderol publishes fault codes for two of its openers. The Rollamatic GEN II lights segments on the bar of its round panel, numbered 1 at the bottom to 9 at the top. The Genesis shows codes on its two-digit display. The Glidermatic GRD, GRD+ and GTS openers have no fault codes, so for those, go straight to the checks.

Rollamatic: segment 2 lit
The safety beam (infrared) is reporting.
What to do: Clear anything between the beams and wipe both lenses, then try again.
Rollamatic: segment 1 lit
The emergency stop is on.
What to do: Call us if you cannot find what has triggered it.
Rollamatic: segment 8 lit
Low voltage.
What to do: Check the power point and your switchboard. If the supply is fine, call us.
Rollamatic: segment 3, 5, 6 or 7 lit
Encoder fault (3), motor reverse (5), motor not working (6) or run timeout (7).
What to do: Stop using the opener and call us. These are not owner fixes.
Rollamatic: segments 1 and 2, or 3 and 4, lit together
The travel limits are reversed (1 and 2), or the door has reached its maximum travel (3 and 4).
What to do: The limits need setting again. Call us.
Genesis: Ir on the display
The safety beam is blocked, or beams are switched on in the settings but none are connected. The door will not close.
What to do: Clear the beam path and wipe the lenses. If your door has no beams fitted, ask us to check the beam setting.
Genesis: counts down from 99, then shows two dashes
Normal start-up after power is restored. The dashes mean ready.
What to do: Nothing to do.
Any coding opener: two beeps when coding a remote
That remote is already in the opener's memory. One beep means it has just been coded.
What to do: Test the remote. It should already work.

Try these in order

Each check rules out a common cause. Stop as soon as the door runs properly.

Before you start: Gliderol says never to adjust or repair the springs or cables yourself, and never to run a door that is off its tracks. Release the opener only with the doorway clear, and lower an open door slowly: with weak springs it can drop.

  1. 1

    Check the drive is engaged

    On a Glidermatic GRD, look at the red lever at the end of the curtain. To re-engage it, return the lever and move the door slowly by hand until you hear it click. On a Rollamatic, pull the red ball once with the door halfway. On a Genesis or GTS, lower the door to closed until the pin clicks back in.

    What it tells you

    If the motor now moves the door, it had been left in manual. If the GRD lever is engaged and the motor still runs without moving the door, the drive pin has broken and needs replacing.

  2. 2

    Make sure the door is not locked

    Check the key lock and any centre lift lock. Gliderol says never to run a Glidermatic or Rollamatic roller door with the lock engaged. If it has been run while locked, switch the power off at the power point straight away.

    What it tells you

    Running an opener against a lock overloads it. If it will not work once the lock is off and the power is back on, the opener needs checking.

  3. 3

    Clear and wipe the safety beams

    Find the two small sensors either side of the opening near the floor. Move anything between them and wipe both lenses with a dry cloth.

    What it tells you

    If the door now closes and a Rollamatic's segment 2 or a Genesis Ir clears, the beam was blocked. If the code stays, a sensor may be out of line or failed, which is a quick fix for us.

  4. 4

    Reset the power

    Switch the opener off at the power point for 60 seconds, then back on. On a GRD+, the next command will only close the door while it finds the floor again, so close it once before opening.

    What it tells you

    Gliderol says travel limits are usually kept through a power reset, but remotes may need coding again. If the opener is still dead with a live power point, the fault is inside it.

  5. 5

    Check the remote battery and vacation mode

    Change the remote battery first: two CR2016s in G+ remotes, one CR2032 in a Rollamatic remote. If no remote works but the wall button does, vacation mode may be on. On a GRD+ or GTS+, holding STOP and CLOSE together for 3 seconds switches it on or off, 5 seconds on a Rollamatic.

    What it tells you

    That same press turns vacation mode on as well as off, so if the remotes stop working after you try it, do it once more. If a remote still will not work, it may need coding again, or the receiver may have a fault.

  6. 6

    Clean the guides, then silicone only

    Wipe the inside of the side guides with a rag. Gliderol's care guide says to lubricate them twice a year with a silicone-based lubricant only, never oil, grease or any petroleum product. Wash the curtain with fresh water and mild soap, never solvents.

    What it tells you

    If the door runs quietly now, it was dust in the guides. If it still drags or sticks at the same point, a guide may be bent or the springs may need re-tensioning.

  7. 7

    Do the balance test

    With the door closed, put it in manual and lift it to about one metre. Gliderol asks for this every six months. It should lift with little effort and stay where you leave it.

    What it tells you

    If it drops, rises or is hard to lift, the springs need balancing by a technician. An unbalanced door also wears out the opener.

When to stop and ask us

  • The motor runs and the door does not move, with the drive engaged
  • The opener was run while the door was locked
  • A Rollamatic shows any code other than segment 2
  • The door fails the balance test
  • The door takes much longer than usual to open or close
  • A spring or cable looks damaged, or the door is off its tracks

Phone 0482 911 999 with which opener you have, what the panel or display shows, and what the door does when you press the button. No question is too small.

If it does need a visit

Roller door repair visits usually take about 45 to 120 minutes. There is no call-out fee, whether you go ahead or not, and you get one fixed price before any work starts.

  • Barrel spring tension checked and reset for correct balance
  • Curtain refitted to the guides, buckling dressed where repairable
  • Side guides realigned and bottom rail straightened or replaced
  • Weather seal and floor gap checked and corrected
  • Roller door motor gears, limits and remotes serviced
More about roller door repair

Gliderol and Glidermatic Troubleshooting, questions we get

Still not sure what is wrong? Phone 0482 911 999 and we will talk it through.

What do the lights on my Rollamatic GEN II panel mean?

The Rollamatic's round panel has a bar of nine segments, and a lit segment points to a fault: segment 2 is the safety beam, segment 8 is low voltage, and the others cover the motor, the encoder and the limits. The full list is at the top of this page. The manual gives no owner fix for them, so apart from clearing the beam, they are a call to us.

My Glidermatic motor runs but the door does not move. Why?

On a Glidermatic GRD the drive sits inside the roll and connects to the door through a red lever, or pin handle, at the end of the curtain. If the motor runs and the door does not, that lever is usually disengaged. Return it and move the door slowly by hand until it clicks in. If it is engaged and the door still will not move, the drive pin has broken and needs replacing.

Why will my Gliderol door only close after a power cut?

That is the GRD+ finding its limits again. After a power failure, a power reset or a manual release, its next command only closes the door so it can find the floor, and open is disabled until that has happened. Close it once and it goes back to normal.

What should I lubricate a Gliderol roller door with?

Gliderol's current care guide says to lubricate roller door guides with silicone-based lubricant only, twice a year or as needed, and never with oil, grease or any petroleum product, because they hold dust in the guides. Wipe the guides clean first.

How often should a Gliderol door be serviced?

Gliderol recommends a service every 24 months for its residential roller doors, and every 18 to 24 months for Glidermatic Heavy Duty, Dual and Rollamatic openers, where missing it voids the five-year motor warranty. Genesis openers need one every 18 months. Near the coast, sooner is better.

Tried the checks and still stuck?

Call and tell us which opener you have, what the panel or display shows, and what the door does when you press the button, and we will tell you what it most likely is. No question is too small, and if it does need a visit there is no call-out fee.

Ask a question Call us