ATA Garage Door Opener Troubleshooting Guide

Trouble with your ATA garage door? When it comes to garage door repair and safety, it is always best to have a professional technician assess the issue. We assess it for free, in most cases the same day, anywhere across Perth. If you would rather take a look yourself first, work through the safe troubleshooting checks below.

  • All Perth covered
  • No call-out fee
  • Same-day service
  • Fixed price before we start

ATA openers tell you a lot if you know where to look. On an EasyRoller roller door opener (GDO-6) or an Ero sectional opener (GDO-11), take the small controls cover off and read the lights. On a Tempo or Syncro, count how many times the main light flashes off after the door moves. Then work through the checks below.

What the lights and beeps mean

The EasyRoller and Ero report through a green OPEN light, a red CLOSE light, a yellow service light and a red coding light under the controls cover, plus a beeper. The Tempo and Syncro flash the main courtesy light off a set number of times, pause, and repeat. If you have an ATS-1, tell us what you see: its two manuals number the flashes differently.

EasyRoller or Ero: green or red keeps flashing, with beeps as the door moves
The door hit something while opening (green) or closing (red).
What to do: Clear the doorway and test the door. If it was damaged, call us.
EasyRoller or Ero: red keeps flashing with nothing in the way
The travel limits may have been cleared.
What to do: Switch off all power, including any battery backup, wait until every light is out (10 to 15 seconds), then reconnect. If red still flashes, the limits need setting again: call us.
EasyRoller or Ero: green and red flashing in turn
The opener is overloaded.
What to do: Pull the release and check the door runs smoothly by hand. If not, stop using the opener and call us.
EasyRoller or Ero: yellow light on
The opener has reached its service count and a service is due.
What to do: Book a service. The door still works in the meantime.
EasyRoller or Ero: yellow light flashing, with a run of beeps
The opener has detected a fault.
What to do: Count the beeps, then press SET once to reset. If it comes back, call us with the number of beeps.
EasyRoller or Ero: green flashing rapidly
Mains power was interrupted.
What to do: Check the power point and the safety switch at your switchboard.
Tempo or Syncro: 2 flashes
The safety beam is stopping the door.
What to do: Clear the beam path and wipe the lenses. If a beam has failed, holding a coded remote button down for more than 5 seconds closes the door in an emergency; keep watching it close, then call us.
Tempo or Syncro: 4 flashes
The wireless safety beam's battery is low.
What to do: Change the battery in the wireless beam.
Tempo or Syncro: 6 flashes
Maintenance is due.
What to do: Book a service.
Tempo or Syncro: 7 flashes
The backup battery is faulty.
What to do: Call us to test or replace it.
Tempo or Syncro: 8 flashes
The door hit an obstruction.
What to do: Clear the doorway and test. If the door was damaged, call us.
Tempo or Syncro: 9 flashes
The motor is overloaded or stalled.
What to do: Pull the release and check the door runs smoothly by hand. If not, call us.
Syncro: 3 flashes as the door starts, 10 as it stops
The opener is running on its backup battery because mains power is off.
What to do: Check the power point and your switchboard.
Tempo or Syncro: blue close light flashing
The travel limits are not set.
What to do: Call us to set them up.
Tempo or Syncro: red remote light flashing
Vacation mode is locking out the remotes.
What to do: Press the remote button that was set up for vacation mode to turn it off.

Try these in order

Each check rules out a common cause. Stop as soon as the door runs properly.

Before you start: ATA's manuals say not to attempt any adjustment to the door itself: the springs, brackets and hardware are under extreme tension. Release the opener only with the doorway clear, ideally with the door closed, because an open door with weak springs can drop.

  1. 1

    Check the power

    Plug something else, like a hair dryer, into the opener's power point, and look for a tripped safety switch at the switchboard. Rapid green flashes on an EasyRoller or Ero mean the power was interrupted.

    What it tells you

    If the power point is dead, it is an electrical problem rather than the opener. If it is live and the opener shows no lights at all, the fault is inside the opener.

  2. 2

    Clear and wipe the safety beams

    Find the two small sensors near the floor either side of the opening. Move anything between them and wipe both lenses with a dry cloth.

    What it tells you

    If the door now closes and the Tempo or Syncro stops flashing twice, the beam was blocked. If it keeps happening with nothing in the way, a beam is out of line or failing.

  3. 3

    Check the remote and vacation mode

    Hold a remote button: a steady light means the battery is fine, flashing or no light means it needs a new CR2032. If the battery is fine and no remote works, the opener may be in vacation mode. Press the button that was set up as the vacation button, then try the others.

    What it tells you

    If the remotes work again, it was the battery or vacation mode. Keep spare coin batteries away from children: ATA warns they can cause serious internal burns if swallowed.

  4. 4

    Release it and move the door by hand

    With the door closed, pull the release. On an EasyRoller, pull the handle down until it clicks. On a sectional opener, pull the cord towards the door, and away from the door to re-engage. Then lift the door by hand.

    What it tells you

    ATA says it should run smoothly and take no more than about 20kg. If it is heavy or rough, the door is the problem, not the opener, and running the opener on it will wear the drive.

  5. 5

    Reset a fault

    On an EasyRoller or Ero with a flashing yellow light and beeps, count the beeps, then press SET once. For a red light that keeps flashing, switch off all power, including any battery backup, for 10 to 15 seconds and reconnect.

    What it tells you

    If the door runs normally afterwards, it was a one-off. If the same signal returns, write it down and tell us, because it tells us what to bring.

  6. 6

    Take an overload seriously

    If green and red are flashing in turn, or a Tempo or Syncro flashes nine times, stop using the opener. Release it and check the door by hand as in the release check.

    What it tells you

    An overload almost always means the door has become heavy or is binding, often through tired springs or a bent track. Fixing that first saves the opener.

  7. 7

    Do the monthly safety test

    Lay a 40mm block of timber or a box under the door and close it: the door must touch it and reopen. Then grab the bottom rail halfway through opening: the door must stop.

    What it tells you

    If either test fails, release the opener, use the door by hand only, and call us. ATA also asks for a technician service at 12 months and then every couple of years.

When to stop and ask us

  • Green and red keep flashing in turn, or a Tempo flashes nine times
  • A fault comes back after pressing SET
  • The close light still flashes after a power reset
  • The door takes more than about 20kg to move by hand
  • The motor runs but the chain or belt does not move
  • The monthly safety test fails

Phone 0482 911 999 with which ATA model you have, which lights are on or how many flashes you counted, and what the door does. No question is too small.

If it does need a visit

Motor repair visits usually take about 60 to 120 minutes. There is no call-out fee, whether you go ahead or not, and you get one fixed price before any work starts.

  • Full diagnostic of motor, logic board, capacitor and safety circuit
  • Drive gear and sprocket kits fitted for common Merlin and Steel-Line heads
  • Chain or belt tension set and trolley release checked
  • Travel limits and force settings recalibrated
  • Remotes and wall button re-paired and tested
More about motor repair

ATA Garage Door Opener Troubleshooting, questions we get

Still not sure what is wrong? Phone 0482 911 999 and we will talk it through.

Why is my ATA opener beeping and flashing?

Most often it is a service reminder. Once the opener reaches its service count it lights the yellow service light and beeps at the start of each cycle. A flashing service light with a long run of beeps is a fault instead: count the beeps, press SET once, and call us if it comes back.

What do alternating green and red lights mean on an ATA EasyRoller?

The opener is overloaded. Pull the release and move the door by hand. If it is heavy, rough or sticks, the door needs attention before the opener does, so stop using it and call us.

My ATA remote has stopped working but the wall button works. What now?

Hold a button on the remote: a steady light means the battery is fine, flashing or no light means it needs a new CR2032. If the battery is fine, the opener may be in vacation mode, which locks out every remote except the one used to set it. Press that remote's button to turn it off, then try the others.

Can I reset the travel limits on my ATA opener myself?

ATA puts limit setting in its installation instructions and in the technician's service checklist, not in the owner's routine. If the close light keeps flashing after a power reset, the limits need setting again, and we do that as part of the visit.

Which remote suits my ATA opener?

Current ATA openers use the PTX-6 TrioCode 128 remote, which takes a CR2032 battery. Older openers used the PTX-5 and PTX-4. Tell us the model on the opener's label and we will bring a remote that codes to it.

Tried the checks and still stuck?

Call and tell us which ATA model you have, which lights are on or how many flashes you counted, and what the door does, and we will tell you what it most likely is. No question is too small, and if it does need a visit there is no call-out fee.

Ask a question Call us